Security

Updated February 28, 2022. Written for LMS Version 6.3.

AAA Settings

For a discussion of the config system authentication command, see Managing Authentication Settings

Keypad Lockout

UCC: Inventory > Local Manager Summary > System > LCD

After completing basic configuration, you may choose to disable the front panel keypad using the config system keypad command. This prevents configuration changes from the keypad. The restart, shutdown, and factory reset functions remain available from the keypad at all times.

[admin@LantronixLM]# config system keypad disable
Allow system configuration from the keypad: disabled

[admin@LantronixLM]# config system keypad enable
Allow system configuration from the keypad: enabled

LCD Information

UCC: Inventory > Local Manager Summary > System > LCD

By default, the Local Manager displays status information on the front LCD panel. You can disable this display with the config system lcd command.

[admin@LantronixLM]# config system lcd disable
Display system information on the LCD: disabled

[admin@LantronixLM]# config system lcd enable
Display system information on the LCD: enabled

The LCD will still display menu options when buttons are pressed, but will be blank otherwise.