Lantronix welcomes Uplogix! Learn more here.

iDirect Falcon config rule

Updated March 9, 2021. Written for LMS Version 6.2.

The following rule is designed to monitor an iDirect to see if Falcon is running, and if not, to push the last saved startup config to the iDirect.

config rule iDirectFalconNotRunning
conditions
chassis.boolean1 equals false 4i AND
NOT has-run pushStartupConfig :15m
exit
action pushStartupConfig current
action alarm GENERIC -a "Falcon not running - pushing startup config"
exit

To implement the rule, go to the iDirect's port and schedule a chassis monitor with that rule attached with the following command:

config monitor chassis iDirectFalconNotRunning