Lantronix welcomes Uplogix! Learn more here.

config system management

Updated February 15, 2022. Written for LMS Version 6.2.

Interactive command to associate the Lantronix Local Manager with a Lantronix Control Center. The heartbeat uses between 1 and 20 kilobytes for communication. This command additionally sets NTP to use the server's address.

Command availability

CLI resource: system

Lantronix system: All

LMS offerings: All

Syntax

config system management

Usage

[admin@LantronixLM]# config system management
--- Existing  Values ---
Use  Management Server: n
Hostname or IP: 127.0.0.1
Port: 8443
Heartbeat interval (seconds): 30
Heartbeat band: all
Last successful heartbeat:  (not yet contacted)
Change these? (y/n) [n]: y
--- Enter New Values ---
Use Management Server (y/n/auto) [n]: y
Hostname or IP: [127.0.0.1]: 198.51.51.20
Set ntp location to 198.51.51.20: (y/n) [y]:
Port: [8443]:
Heartbeat interval (seconds): [30]:
Heartbeat during: [all]:
Do you want to commit these changes? (y/n): y

Heartbeat during specifies when the Lantronix Local Manager provides a heartbeat, and may be set to inband, outband, or all.

Minimal heartbeat can be configured from the UCC. The setting is displayed as:

Always use minimal heartbeat: true

You will only be prompted for the NTP location if the Local Manager has not been managed by a Lantronix Control Center before.

Note: If the Local Manager has been managed by the Lantronix Control Center at some time in the past, this command will not configure NTP. In this situation, use the config system ntp command to set the Lantronix Control Center as the Local Manager's NTP server.

In the Lantronix web interface

Inventory > group page> Network > Management Server - specific to this inventory group

Inventory > Local Manager page > Network > Mangement Server - specific to this system

History

3.4 - This command was introduced

4.5 - Minimal Heartbeat option (display only)

Related commands

  • show system management
  • config system ntp
  • config system archive

Not finding what you're looking for?

The LEVEL Technical Services team is standing by 24/7/365 to answer any questions you may have about the installation, configuration, and usage of our products.