Interactive command to configure SMTP server settings for sending in-band and outband mail alerts. When alarms trigger, the Lantronix Local Manager collects them and sends them every two minutes to users who have subscribed to the alarms.
CLI resource: system
Lantronix system: All
LMS offerings: All
config system email
For maximum fault tolerance, use separate mail servers when operating outband.
[admin@LantronixLM]# config system email
--- Existing Values ---
In-Band SMTP Server: 172.16.100.1
In-Band from address: Aus01@xyzco.com
In-Band SMTP Port: 25
Use user authentication in-band: no
Prefer SSL for in-band email: no
Out-of-Band SMTP Server: 198.6.1.2
Out-of-Band from address: Aus01@xyzco.com
Out-of-Band SMTP Port: 25
Use user authentication out-of-band: no
Prefer SSL for out-of-band email: no
Change these? (y/n) [n]: