IBM Tivoli SNMP Integration

Updated March 9, 2021. Written for LMS Version 6.2.

This guide contains instructions for configuring a Lantronix Control Center to send SNMP traps to a Tivoli Netcool instance. Instructions for installing and customizing a rules file in Tivoli follow.

Requirements

  • Lantronix Control Center on version 3.5 or higher
  • Tivoli Netcool version 7.3.1
  • Mttrapd SNMP probe installed on Tivoli Netcool instance

Configuring the Lantronix Control Center

UCC: Administration > Server Settings > SNMP

To configure the Lantronix Control Center to send SNMP traps to a Tivoli Netcool instance, navigate to the Administration tab in your Control Center's GUI. Under Server Settings, open the SNMP Settings section. Click the Use SNMP check box, enter the IP address or hostname of your Tivoli Netcool instance in the Primary Host Name section. If your Tivoli Netcool instance is configured to listen for traps on a port other then 162, change the port from the default of 162. Finally, enter the read community you would like to use for the SNMP traps.

Lantronix Control Center SNMP Settings

The Lantronix Control Center can be configured to send SNMP traps to up to two SNMP receivers. Configuring either the primary or secondary for Tivoli Netcool is acceptable.

Installing MTTRAPD Rules File on Tivoli Netcool

To install the MTTRAPD rules file for on your Tivoli Netcool instance, copy the provided mttrapd.rules file into the /opt/IBM/tivoli/netcool/omnibus/probes/linux2x86/ directory. Alternatively the contents of that file can be appended into the existing mttrapd.rules file. After copying or appending the file, restart the mttrapd process.

Customizing the MTTRAPD Rules File on Tivoli Netcool

To change the severity of incoming traps in Tivoli Netcool, edit the mttrapd.rules file and change the each trap's Severity field to the severity level appropriate to the event's importance (see table one below as an example).

Lantronix Control Center SNMP Settings

Table 1: Netcool/OMNIbus Severity Levels

Severity Description Desktop Color
5 Critical Red
4 Major Orange
3 Minor Yellow
2 Informational Blue
1 Indeterminate Purple
0 Clear Green

Sample mttrapd.rules

Download a sample file here.